6.3 Connection Settings

6.3.1 Setting Servo/Spindle Drive Unit's DIP Switches

Set the DIP switches ((2) in fig.) to the standard settings (turn all the switches OFF).
The switches are turned OFF when they are downward position as below.
Turning these switches ON sets the corresponding axis to the unused axis. (Do not turn ON the rightmost switch.)
Carry out the unused axis setting when you use the multi-axes drive unit that has any unused axis.
For those axes that are supposed to be used later, refer to "Setting up without Connecting to the Motor/ Drive unit"
instead of doing this setting.
L
(1)
8
7 9
6
5
4
3
2
1 F
0
(1) Axis No. setting switch
(2) Unused axis setting switch
(3) Motor side detector connection connector
(4) Motor power supply output connector
<MDS-DM-SPV series>
The setting of the axis number is fixed as follows in the MDS-DM-SPV Series.
Setting the MDS-DM-SPV Series
When using the MDS-DM-SPV Series, MDS-D and MDS-DM-V3 together, the axis numbers for the MDS-DM-SPV
Series are fixed as above. Set the axis numbers from 4th axis or 5th axis.
M
S
8
8
7 9
7 9
A
6
A
6
A
B
5
B
5
B
C
4
C
4
C
D
3
D
3
D
E
2
E
2
E
1 F
1 F
0
0
L
(3)
M
S
MDS-DM-V3
1st axis
2nd axis
3rd axis
4th axis
(2)
L M S
S
(4)
M
L
L : L axis
M: M axis
S : S axis
Bottom view
Details
Spindle axis
L-axis
M-axis
S-axis (MDS-DM-SPV3/SPV3F)