Making Communication Settings; Setting Ethernet Connection (For Gt16) - Mitsubishi Electric C70 Setup Manual

Hide thumbs Also See for C70:
Table of Contents

Advertisement

2.1.2 Making Communication Settings

Make communication settings on a GT Designer3 project.
Refer to the following according to the connection type you use.
- Ethernet connection (for GT16): Section 2.1.2.1
- Ethernet connection (for GT15): Section 2.1.2.2
- Bus connection (for GT15/GT16): Section 2.1.2.3

2.1.2.1 Setting Ethernet Connection (for GT16)

This section explains the setting procedure for Ethernet connection of GOT1000 Series GT16.
Connect a Ethernet cable to the CNC CPU module and the GOT Ethernet interface.
The following two IP addresses need to be set in order to establish the Ethernet connection.
GOT's IP address (192.168.1.1 in this manual)
CNC CPU module's IP address (192.168.1.2)
GT Designer3
Rear view
Ethernet interface
(Note 1) When connecting to a personal computer and a module with USB interface, an electric shock or a module
failure may occur depending on the model of a personal computer or the service condition.
Be sure to refer to "Items related to connection" on "Precautions for Safety" before connecting them.
(Note 2) Unless there is a specific reason, set the CNC CPU default IP address (192.168.1.2). If any other IP adress is
set, the backup data created with GOT backup and restore function cannot be restored to the replaced CNC
CPU module, which has a default IP address.
Setting procedures without using the "New Project Wizard" on GT Designer3 are as follows.
GOT1000 Series GT16
or
USB
GT09-C20USB-5P
GT09-C30USB-5P
IP address: 192.168.1.2
(SVGA / XGA)
IP address: 192.168.1.1
100BASE-T
Cross
or
CNC CPU
Q173NCCPU
C70 Setup Manual
2.1 GT Designer3
100BASE-T
Straight
7

Advertisement

Table of Contents
loading

Table of Contents