MITSUBISHI CNC
Appendix 2 Explanation of Alarms
A01 MULTI CPU ERROR 4003
Details
- The exclusive instruction designated by the program has an incorrect number of devices.
Remedy
- Read the common information of the error using a peripheral device, check error step corresponding
to its numerical value (program error location), and correct the problem.
A01 MULTI CPU ERROR 4004
Details
- The exclusive instruction designated by the program a device which cannot be used.
Remedy
- Read the common information of the error using a peripheral device, check error step corresponding
to its numerical value (program error location), and correct the problem.
A01 MULTI CPU ERROR 4010
Details
- There is no END (FEND) instruction in the program.
Remedy
- Read the common information of the error using a peripheral device, check error step corresponding
to its numerical value (program error location), and correct the problem.
A01 MULTI CPU ERROR 4020
Details
- The total number of internal file pointers used by the program exceeds the number of internal file
pointers set in the parameters.
Remedy
- Read the common information of the error using a peripheral device, check error step corresponding
to its numerical value (program error location), and correct the problem.
A01 MULTI CPU ERROR 4021
Details
- The pointer Nos. overlap between common and local pointers, which are assigned to files.
Remedy
- Read the common information of the error using a peripheral device, check error step corresponding
to its numerical value (program error location), and correct the problem.
A01 MULTI CPU ERROR 4030
Details
- The allocation pointer Nos. assigned by files overlap.
Remedy
- Read the common information of the error using a peripheral device, check error step corresponding
to its numerical value (program error location), and correct the problem.
A01 MULTI CPU ERROR 4100
Details
- The instruction cannot process the contained data.
Remedy
- Read the common information of the error using a programming tool, check error step corresponding
to its numerical value (program error location), and correct the problem.
506