Mitsubishi Electric C70 Setup Manual page 241

Hide thumbs Also See for C70:
Table of Contents

Advertisement

MITSUBISHI CNC
Appendix 1 Explanation of Parameters
【#21104】 add04
bit0: Search mode hold (word edit)
Set hold/non-hold of search mode.
0 : When a search is executed, go back to the 1st menu. (conventional)
1 : Hold the search mode even if a search is executed.
bit2: Search menu ON (screen edit)
Switch operation methods for data search.
0 : Execute string search downward. (conventional)
1 : Switch to search menu for the word/string search to execute upward/downward search.
bit3: Default insert ON (screen edit)
Switch the mode between insert/write.
0 : Turn ON the overwrite mode when the screen is switched. (conventional)
1 : Turn ON the insert mode when the screen is switched, and it is held until the next screen
bit4: Switching the number of lines to feed (screen edit)
Switch the page feeding for the edit programs.
0 : Feed 11 lines.(conventional)
1 : Feed 12 lines in screen units.
【#21105】 add05
bit0: Program in-position type 2
Select the operation type of programmable in-position check.
0: When "#1193 inpos" is "1" or "3", ",I" command is enabled. The maximum difference between
1: Regardless of "#1193 inpos" setting, ",I" command is enabled. Only ",I" command value is
bit1: Macro single speeding up
Select a state of continuous operation when "#8101 macro single" is enabled.
0: Disable
1: Enable
bit2: Conventional Emergency stop canceling method
Select the method for emergency stop cancel process.
0: Check the hot line gate OFF signal and cancel the emergency stop
1: Conventional method (without checking the gate OFF signal)
* Normally, "0" is set. Setting "1" is to avoid a failure in the emergency stop cancel.
【#21113】 add13
bit0: DeviceNet error monitor
Select whether to enable the DeviceNet error monitoring.
0 : Disable
1 : Enable
【#21125(PR)】 SSU_num Number of dual signal modules
Set the number of dual signal modules to install.
Setting to "0" means that the dual-signal comparison is not carried out.
---Setting range---
0 to 3
224
switching.
",I" command value and the parameter setting value is enabled.
enabled.