Appendix 3.2.2 Notes - Mitsubishi Electric C70 Setup Manual

Hide thumbs Also See for C70:
Table of Contents

Advertisement

Appendix 3.2.2 Notes

(1) Display priority
When several alarms occurred at the same time, the most crucial alarm is selected according to the following chart
and displayed.
(2) Display of axes
Each axis is allocated to each bit according to the following rule. Hexadecimal number is displayed on 7-segment
LED.
(Note 1) "*" in the first digit indicates the spindle.
(Note 2) "_" in the first digit indicates PLC axis.
(Note 3) When an error occurred on several axes, one of the axes is indicated. The indication priority is; (1) NC
axis, (2) PLC axis and then (3) spindle.
bit
F
(Example 1) "004" (bit2 is ON) for 3rd NC axis
(Example 2) "003" (bit0 and bit1 is ON) for 1st and 2nd NC axis
(Example 3) "*01" (bit0 is ON) for spindle(S)
(Example 4) "_28" (bit3 and bit5 are ON) for 4th PLC axis and 6th PLC axis
(Example 5) "011" (bit0 and bit1 are ON) for 1st and 5th NC axes, 2nd PLC axis and spindle(S)
Alarm type
WDT error
Battery alarm
Multi-CPU error
System alarm
Servo alarm
MCP alarm
Emergency stop
Built-in PLC alarm
Program error
Servo warning
MCP warning
System warning
Operation error
Stop code
E
D
C
B
A
9
8
Priority
High
Low
7
6
5
4
3
2
1
C70 Setup Manual
Appendix 3.2 Alarm/Stop codes
0
Axis name(Spindle)
1st (S)
2nd (T)
3rd (M)
4th (N)
5th (P)
6th (Q)
7th (R)
8th
595