【#13229】 SP229 SFNC9 Spindle function 9
Select the spindle functions.
Functions are allocated to each bit.
Set this in hexadecimal format.
bit F : ssc SLS (Safely Limited Speed) function
0: Disable 1: Enable
bit E :
Not used. Set to "0".
bit D : rps Safely limited speed setting unit
0: Normal 1: 100°/min
bit C : sdt2 Specified speed output digital signal 2 output
0: Normal 1: Enable
bit B-9 :
Not used. Set to "0".
bit 8 : sto Dedicated wiring STO function
Set this parameter to use dedicated wiring STO function.
0: Dedicated wiring STO function unused
bit 7-1 :
Not used. Set to "0".
bit 0 : omrffon OMR-FF control enabled
0: Disable  1: Enable
Appendix 1.6 Spindle Parameters
omrffon
sto
sdt2
rps
ssc
1: Dedicated wiring STO function used