【#7694】 <check> Selection of area check method PSW20
When position switch area checking at high speed is selected, specify the mode of area checking,
i.e., whether to use the command type machine position or detector feedback position, for each
position switch point.
0: Use the command type machine position as the machine position for position switch area
1: Use the detector feedback position as the machine position for position switch area checking.
【#7701】 <axis> Axis name PSW21
Specify the name of the axis for which a position switch is provided.
---Setting range---
NC axis: axis name (X, Y, Z, U, V, W, A, B, or C)
【#7702】 <dog1> Imaginary dog position 1 PSW21
When the machine enters the range between imaginary dog positions 1 and 2, a signal is output to
the PLC.
Part system 1 device: X67C
Part system 2 device: X6FC
---Setting range---
-99999.999 to 99999.999 (0.001mm)
【#7703】 <dog2> Imaginary dog position 2 PSW21
When the machine enters the range between imaginary dog positions 1 and 2, a signal is output to
the PLC.
Part system 1 device: X67C
Part system 2 device: X6FC
---Setting range---
-99999.999 to 99999.999 (0.001mm)
【#7704】 <check> Selection of area check method PSW21
When position switch area checking at high speed is selected, specify the mode of area checking,
i.e., whether to use the command type machine position or detector feedback position, for each
position switch point.
0: Use the command type machine position as the machine position for position switch area
1: Use the detector feedback position as the machine position for position switch area checking.
【#7711】 <axis> Axis name PSW22
Specify the name of the axis for which a position switch is provided.
---Setting range---
NC axis: axis name (X, Y, Z, U, V, W, A, B, or C)
【#7712】 <dog1> Imaginary dog position 1 PSW22
When the machine enters the range between imaginary dog positions 1 and 2, a signal is output to
the PLC.
Part system 1 device: X67D
Part system 2 device: X6FD
---Setting range---
-99999.999 to 99999.999 (0.001mm)
【#7713】 <dog2> Imaginary dog position 2 PSW22
When the machine enters the range between imaginary dog positions 1 and 2, a signal is output to
the PLC.
Part system 1 device: X67D
Part system 2 device: X6FD
---Setting range---
-99999.999 to 99999.999 (0.001mm)
checking.
checking.
C70 Setup Manual
Appendix 1.13 Position Switches