Mitsubishi Electric C70 Setup Manual page 448

Hide thumbs Also See for C70:
Table of Contents

Advertisement

T02 Reset signal ON 0203
Details
The reset has been entered.
Remedy
- The program execution position has returned to the start of the program. Execute automatic
operation from the start of the machining program.
T02 Auto operation pause signal ON 0204
Details
The "feed hold" switch is ON.
Remedy
- Press the CYCLE START switch to resume the automatic operation.
T02 Operation mode changed 0205
Details
The operation mode has changed to another mode during automatic operation.
Remedy
- Return to the original automatic operation mode, and press the CYCLE START switch to resume the
automatic operation.
T02 Acc/dec time cnst too large 0206
Details
The acceleration and deceleration time constants are too large. (This alarm occurs with the system
alarm Z59.)
Remedy
- Set a larger value for "#1206 G1bF(Maximum speed)".
- Set a smaller value for "#1207 G1btL(Time constant)".
- Set a lower cutting speed.
T02 Abs posn detect alarm occurred 0215
Details
An absolute position detection alarm occurred.
Remedy
- Clear the absolute position detection alarm.
T03 Single block stop signal ON 0301
Details
The SINGLE BLOCK switch on the machine operation panel is ON.
The SINGLE BLOCK or MACHINE LOCK switch changed.
Remedy
- Press the CYCLE START switch to resume the automatic operation.
T03 Block stop cmnd in user macro 0302
Details
A block stop command was issued in the user macro program.
Remedy
- Press the CYCLE START switch to resume the automatic operation.
T03 Operation mode changed 0303
Details
Automatic mode changed to another automatic mode.
Remedy
- Return to the original automatic operation mode, and press the CYCLE START switch to resume the
automatic operation.