【#7654】 <check> Selection of area check method PSW16
When position switch area checking at high speed is selected, specify the mode of area checking,
i.e., whether to use the command type machine position or detector feedback position, for each
position switch point.
0: Use the command type machine position as the machine position for position switch area
1: Use the detector feedback position as the machine position for position switch area checking.
【#7661】 <axis> Axis name PSW17
Specify the name of the axis for which a position switch is provided.
---Setting range---
NC axis: axis name (X, Y, Z, U, V, W, A, B, or C)
【#7662】 <dog1> Imaginary dog position 1 PSW17
When the machine enters the range between imaginary dog positions 1 and 2, a signal is output to
the PLC.
Part system 1 device: X678
Part system 2 device: X6F8
---Setting range---
-99999.999 to 99999.999 (0.001mm)
【#7663】 <dog2> Imaginary dog position 2 PSW17
When the machine enters the range between imaginary dog positions 1 and 2, a signal is output to
the PLC.
Part system 1 device: X678
Part system 2 device: X6F8
---Setting range---
-99999.999 to 99999.999 (0.001mm)
【#7664】 <check> Selection of area check method PSW17
When position switch area checking at high speed is selected, specify the mode of area checking,
i.e., whether to use the command type machine position or detector feedback position, for each
position switch point.
0: Use the command type machine position as the machine position for position switch area
1: Use the detector feedback position as the machine position for position switch area checking.
【#7671】 <axis> Axis name PSW18
Specify the name of the axis for which a position switch is provided.
---Setting range---
NC axis: axis name (X, Y, Z, U, V, W, A, B, or C)
【#7672】 <dog1> Imaginary dog position 1 PSW18
When the machine enters the range between imaginary dog positions 1 and 2, a signal is output to
the PLC.
Part system 1 device: X679
Part system 2 device: X6F9
---Setting range---
-99999.999 to 99999.999 (0.001mm)
【#7673】 <dog2> Imaginary dog position 2 PSW18
When the machine enters the range between imaginary dog positions 1 and 2, a signal is output to
the PLC.
Part system 1 device: X679
Part system 2 device: X6F9
---Setting range---
-99999.999 to 99999.999 (0.001mm)
checking.