【#13226】 SP226 SFNC6 Spindle function 6
Select the spindle functions.
Functions are allocated to each bit.
Set this in hexadecimal format.
bit F : clt Spindle monitor load inertia ratio
0: Normal 1: Display
bit E : obs Disturbance observer
0: Normal 1: Enable
bit D : vup High response acceleration / deceleration
This suppresses a temporal delay which occurs when the target speed is attained from acceleration
and when the spindle stops from deceleration.
0: Normal acceleration/deceleration 1: High response acceleration/deceleration Enable
bit C : tqof Spindle output stabilization during acceleration
0: Normal 1: Disable
bit B-9 :
Not used. Set to "0".
bit 8 : r2c Temperature compensation adjustment indicator
0: Normal 1: Display
bit 7-6 :
Not used. Set to "0".
bit 5 : pon IPM spindle pulse application magnetic pole estimation
0: Normal 1: Enable
bit 4-0 :
Not used. Set to "0".
C70 Setup Manual
Appendix 1.6 Spindle Parameters
pon
r2c
tqof
vup
obs
clt
335