Mitsubishi Electric C70 Setup Manual page 243

Hide thumbs Also See for C70:
Table of Contents

Advertisement

MITSUBISHI CNC
Appendix 1 Explanation of Parameters
【#21149(PR)】 Safety_passwd Safety observation parameter password
Set a password for changing the safety observation parameter settings.
The password will be enabled after the power is turned OFF and ON.
The password locks the following parameter settings:
[Base specifications parameters]
- #1329 Emgcnt Emergency stop contactor shut-off time
- #1330 MC_dp1 Contactor weld detection device 1
- #1331 MC_dp1 Contactor weld detection device 2
- #1357 mchkt1 Contactor operation check allowed time 1
- #1368 SfAlmRstD Safety observation alarm reset inputting device
- #21125 SSU_num Number of dual signal modules
- #21126 to 21141 SODR_1 to 16 Speed monitor input device door 1 to 16
- #21142 SSU_delay Dual-signal comparison tolerance time
- #21143 to 21145 SSU_Dev1 to Dev3 Dual signal module device 1 to 3
- #21149 Safety_passwd Safety observation parameter password
- #21151 SC_EQP_1 Safety device mounting information 1
- #21152 SC_EQP_2 Safety device mounting information 2
- #21153 SC_EQP_CHK1 Safety device mounting information check 1
- #21154 SC_EQP_CHK2 Safety device mounting information check 2
- #21155 Built in Safety Built in safety circuit
- #21156 SSU_wrg Reset Comparison error warning reset cancel
- #21157 SC_EQP_3 Safety device mounting information 3
- #21158 SC_EQP_4 Safety device mounting information 4
- #21159 SC_EQP_CHK3 Safety device mounting information check 3
- #21160 SC_EQP_CHK4 Safety device mounting information check 4
- #21161 SftySgnlChkTrg Dual signal check-time change
- #21162 mulstepssc Multi-step speed monitor enabled
- #21163 InvalidDoorSgnl Door monitor disabled
[Axis specifications parameters]
- #2118 S_DSI Speed monitor Door selection
- #2140 S_Fil Speed monitor Error detection time during servo OFF
- #2180 S_DIN Speed observation input door No.
- #2181 to #2184 sscfeed1 to sscfeed4 Safety observation speed 1 to 4
[Servo parameters]
- #2233 SV033 SSF2 Servo function selection 2/ bitD rps Safety observation safety speed setting
increment
- #2248 SV048 EMGrt Vertical axis drop prevention time
- #2255 SV055 EMGx Max. gate off delay time after emergency stop
- #2282 SV082 SSF5 Servo function selection 5/ bitC,D,E,F dis Digital signal input selection
- #2313 SV113 SSF8 Servo function selection 8/ bitF ssc Safety observation function
- #2438 SV238 SSCFEED Safety observation Safety speed
- #2439 SV239 SSCRPM Safety observation Safety motor speed
[Spindle parameters]
- #3071 SscDrSelSp Speed monitor Door selection
- #3072 Ssc Svof Filter Sp Speed monitor Error detection time during servo OFF
- #3140 S_DINSp Speed observation input door No.
- #3141 to #3144 sscfeedsp1 to sscfeedsp4 Safety observation speed 1 to 4
[Spindle specifications parameters]
- #13055 SP055 EMGx Max. gate off delay time after emergency stop
- #13227 SP227 SFNC7 Servo function 7/ bitC,D,E,F dis Digital signal input selection
- #13229 SP229 SFNC9 Spindle function 9/ bitD rps Safety observation speed setting unit, bitF ssc
Safety observation function
- #13238 SP238 SSCFEED Safety observation safety speed
- #13239 SP239 SSCRPM Safety observation safety motor speed
---Setting range---
0 to 99999