Appendix 1 Explanation of Parameters
【#1193】 inpos Validate in-position check
Select the manner of how to check deceleration when a positioning command is being issued.
0: Command deceleration check
1: In-position check
2: Command deceleration check (Commanded deceleration check is executed when cutting feed
3: In-position check (Commanded deceleration check is executed when cutting feed is shifted to
For the details of each setting values, refer to "Deceleration Check" - "Deceleration Check and
Parameters".
【#1194】 H_acdc Time constant 0 for handle feed
Select the time constant for manual handle feed.
0: Use time constant for G01
1: Time constant 0 (step)
【#1195】 Mmac Macro call for M command
Select whether to enable or disable M command macro call of user macro.
0: Disable
1: Enable
【#1196】 Smac Macro call for S command
Select whether to enable or disable S command macro call of user macro.
0: Disable
1: Enable
【#1197】 Tmac Macro call for T command
Select whether to enable or disable T command macro call of user macro.
0: Disable
1: Enable
【#1198】 M2mac Macro call with 2nd miscellaneous code
Select whether to enable or disable 2nd miscellaneous command macro call of user macro.
0: Disable
1: Enable
【#1199(PR)】 Sselect Select initial spindle control
Select the initial condition of spindle control after power is turned ON.
0: 1st spindle control mode (G43.1)
1: 2nd spindle control mode (G44.1)
【#1200(PR)】 G0_acc Validate acceleration and deceleration with inclination constant G0
Select the acceleration and deceleration type when a rapid traverse command is issued.
0: Acceleration and deceleration with constant time (conventional type)
1: Acceleration and deceleration with a constant angle of inclination
【#1201(PR)】 G1_acc Validate acceleration and deceleration with inclination constant G1
Select the acceleration and deceleration type when a linear interpolation command is issued.
0: Acceleration and deceleration with constant time (conventional type)
1: Acceleration and deceleration with a constant angle of inclination
【#1202】 mirofs Distance between facing turrets (for L system only)
Set the distance between tools (edges) (between facing turrets).
---Setting range---
0 to 99999.999 (mm)
196
(Positioning is completed when the deceleration is completed at the acceleration/deceleration
speed commanded from the control unit.)
(Positioning is completed when the servo drive unit detects the machine having reached within
a set distance from the end point. This set distance is determined in "#2224 SV024".)
is shifted to rapid traverse.)
rapid traverse.)