Appendix 1 Explanation of Parameters
【#8111】 Milling Radius
Set whether to specify the program travel amount by the radius value of all axes in milling or by
setting of each axis.
Normally, the radius value command of all axes is set.
0: All axes radius value command
1: Each axis setting ("#1019")
【#8201】 AX. RELEASE
Select the function to remove the control axis from the control target.
0: Control as normal.
1: Remove from control target.
【#8202】 OT-CHECK OFF
Select whether to enable the stored stroke limit II function set in #8204 and #8205.
0: Enable
1: Disable
【#8203】 OT-CHECK-CANCEL
When the simple absolute position method ("#2049 type" is "9") is selected, the stored stroke limits I,
II (or IIB) and IB can be disabled until the first reference position return is executed after the power is
turned ON.
0: Enable (according to #8202)
1: Temporarily cancel
(Note) "#8203 OT-CHECK-CANCEL" affects all the stored stroke limits.
【#8204】 OT-CHECK-N
Set the coordinates of the (-) direction in the movable range of the stored stroke limit II or the lower
limit coordinates of the prohibited range of stored stroke limit IIB.
If the sign and value are the same as #8205, the stored stroke limit II (or IIB) will be invalid.
If the stored stroke limit IIB function is selected, the prohibited range will be between two points even
when #8204 and #8205 are set in reverse. When II is selected, the entire range will be prohibited if
#8204 and #8205 are set in reverse.
---Setting range---
-99999.999 to 99999.999 (mm)
【#8205】 OT-CHECK-P
Set the coordinates of the (+) direction in the movable range of the stored stroke limit II or the upper
limit coordinates of the prohibited range of stored stroke limit IIB.
---Setting range---
-99999.999 to 99999.999 (mm)
【#8206】 TOOL CHG. P
Set the coordinates of the tool change position for G30. n (tool change position return).
Set with coordinates in the basic machine coordinate system.
---Setting range---
-99999.999 to 99999.999 (mm)
【#8207】 G76/87 IGNR (for M system only)
Select whether to enable the shift operation at G76 (fine boring) and G87 (back boring).
0: Enable
1: Disable
【#8208】 G76/87 (-) (for M system only)
Select the shift direction at G76 and G87.
0: Shift to (+) direction
1: Shift to (-) direction