Mitsubishi Electric C70 Setup Manual page 209

Hide thumbs Also See for C70:
Table of Contents

Advertisement

MITSUBISHI CNC
Appendix 1 Explanation of Parameters
【#1152】 I_G20 Initial command unit
Select inch or metric command mode at power-ON or resetting.
0 : Metric command (G21 command state)
1 : Inch command (G20 command state)
This selection is enabled at reset input.
Related parameter : "#1226 bit6" Set up and display unit selection
【#1154(PR)】 pdoor
Not used. Set to "0".
【#1155】 DOOR_m Signal input device 1 for door interlock II
Set a fixed device No. (X device No.) to input the door interlock II signal.
Using this device can realize the same operation as the door open II signal input, without passing
through the PLC.
"000" can not be used as a fixed device No.
When not using the fixed device No, set this to "100".
(Note) When you set a device No. with this parameter, make sure also to set the same No. to
---Setting range---
000 to 2FF(hexadecimal)
【#1156】 DOOR_s Signal input device 2 for door interlock II
Set a fixed device No. (X device No.) to input the door lock II signal.
Set the same value as #1155.
---Setting range---
000 to 2FF(hexadecimal)
【#1157】 F0atrn
Not used. Set to "0".
【#1158】 F0atno
Not used. Set to "0".
【#1164】 ATS Automatic tuning function
Select whether to enable or disable the automatic tuning function.
0: Disable
1: Enable
(Note) Enable this parameter when using MS Configurator.
【#1166】 fixpro Fixed cycle editing
Select a type of program dealt on the edit/program list/data in/out screen, general program or fixed
cycle.
0: General programs can be edited, etc.
1: Fixed cycles can be edited, etc.
【#1167】 e2rom
Not used. Set to "0".
【#1168】 test Simulation test
Select the test mode for the control unit.
In the test mode, test is performed with a hypothetical reference position return complete even
though the real reference position return hasn't been completed. This is limited to test operation of
the control unit itself, and must not be used when the machine is connected.
0: Normal operation mode
1: Test mode
192
"#1156".
Although later CNC software versions allow constant connection of MS Configurator while this
parameter is set to "0", the available functions are limited.