【#3008】 smax 4 Maximum rotation speed (Gear: 11)
Set the maximum spindle rotation speed which is actually commanded when gear 11 is selected.
Set this as smax4(#3008)<= slimit4(#3004).
By comparing the S command value and the values of gear 1 - 4, a spindle gear shift command will
be output automatically.
---Setting range---
0 to 99999 (r/min)
【#3009】 ssift 1 Shift rotation speed (Gear: 00)
Set the spindle speed for gear shifting with gear 00.
(Note) Setting too large value may cause a gear nick when changing gears.
---Setting range---
0 to 32767 (r/min)
【#3010】 ssift 2 Shift rotation speed (Gear: 01)
Set the spindle speed for gear shifting with gear 01.
(Note) Setting too large value may cause a gear nick when changing gears.
---Setting range---
0 to 32767 (r/min)
【#3011】 ssift 3 Shift rotation speed (Gear: 10)
Set the spindle speed for gear shifting with gear 10.
(Note) Setting too large value may cause a gear nick when changing gears.
---Setting range---
0 to 32767 (r/min)
【#3012】 ssift 4 Shift rotation speed (Gear: 11)
Set the spindle speed for gear shifting with gear 11.
(Note) Setting too large value may cause a gear nick when changing gears.
---Setting range---
0 to 32767 (r/min)
【#3013】 stap 1 Synchronous tapping 1st step rotation speed (Gear: 00)
Set the speed which switches from 1st step to 2nd step in synchronous tapping multi-step
acceleration/deceleration control when gear 00 is selected.
The inclination of linear acceleration/deceleration control for 1st step is determined by the ratio of
stap1(#3013) to stapt1(#3017).
When the inclination is not set after 2nd step or it is higher than that of 1st step, the acceleration/
deceleration control is executed with the same inclination as the 1st step for the rotation speed of
stap1 or higher.
---Setting range---
0 to 99999 (r/min)
【#3014】 stap 2 Synchronous tapping 1st step rotation speed (Gear: 01)
Set the speed which switches from 1st step to 2nd step in synchronous tapping multi-step
acceleration/deceleration control when gear 01 is selected.
The inclination of linear acceleration/deceleration control for 1st step is determined by the ratio of
stap2(#3014) to stapt2(#3018).
When the inclination is not set after 2nd step or it is higher than that of 1st step, the acceleration/
deceleration control is executed with the same inclination as the 1st step for the rotation speed of
stap2 or higher.
---Setting range---
0 to 99999 (r/min)