Mitsubishi Electric C70 Setup Manual page 229

Hide thumbs Also See for C70:
Table of Contents

Advertisement

MITSUBISHI CNC
Appendix 1 Explanation of Parameters
【#1312】 T_base Tool life management standard number
Set the standard No. for the tool life management.
When the value specified by the T code command exceeds the set value in this parameter, the set
value will be subtracted from the command value, which will be used as tool group No. for tool life
management.
When the value specified by the T code command is equal to or less than the set value, the T code
will be handled as a normal T code and not subjected to tool life management.
When "0" is set in this parameter, the T code command will always specify a group No. (Valid for M-
system tool life management II.)
---Setting range---
0 to 9999
【#1313】 TapDwl Hole bottom wait time
Set the hole bottom wait time of synchronous tap.
Comparing with P command, a greater value will be applied as the hole bottom wait time. When an
in-position check is performed at the hole bottom, the dwell for specified period of time will be
completed after the completion of the in-position check.
(Note) This parameter is enabled when "#1223 aux07 /BIT3, BIT4" is set "1".
---Setting range---
0 to 999 (ms)
【#1314】 TapInp In-position check width for tapping hole bottom(tap axis)
Set the hole bottom in-position check width for synchronous tapping.
The value of "#2224 sv024" is applied when "0" is set.
(Note) This parameter is enabled when "#1223 aux07/bit3,bit4" is set "1".
---Setting range---
0 to 99.999 (mm)
【#1323(PR)】 chopsel Chopping command method
Select how to command chopping.
0: Command with PLC interface
1: Command with a G code
【#1329】 Emgcnt Emergency stop contactor shut-off time
Set the time taken for the drive section's main power to be shut-off when the confirmation of all the
axes' stop failed after the emergency stop state.
The contactor shut-off signal is output as soon as all the axes are confirmed stopped if the
confirmation is done prior to the set time.
When there is no safety observation option or "0" is set, the shut-off time will be 30(s).
---Setting range---
0 to 60 (s)
【#1330(PR)】 MC_dp1 Contactor weld detection device 1
When safety observation is executed, set the device of a safety signal unit (the sequencer side
device No.) to input the contactor's auxiliary b contact signal used for the contactor weld detection.
If "0" is set, weld detection will not be executed.
---Setting range---
0000 to 01FF (HEX)
【#1331(PR)】 MC_dp2 Contactor weld detection device 2
When safety observation is executed, set the device of a safety signal unit (the sequencer side
device No.) to input the contactor's auxiliary b contact signal used for the contactor weld detection.
If "0" is set, weld detection will not be executed.
---Setting range---
0000 to 01FF (HEX)
212

Advertisement

Table of Contents
loading

Table of Contents