Mitsubishi Electric C70 Setup Manual page 263

Hide thumbs Also See for C70:
Table of Contents

Advertisement

MITSUBISHI CNC
Appendix 1 Explanation of Parameters
【#2161】 exdcax2 External deceleration speed 2
Set the upper limit of the feedrate when the external deceleration signal is ON and only one axis is
moved. In automatic operation, the upper limit of the combined speed is applied.
Set #2086 when using the external deceleration for each axis, and #2161 - #2165 when using the
external deceleration 2nd step or later.
This parameter is enabled when "#1239 set11/bit6" is set to "1".
---Setting range---
1 to 1000000(mm/min)
【#2162】 exdcax3 External deceleration speed 3
Set the upper limit of the feedrate when the external deceleration signal is ON and only one axis is
moved. In automatic operation, the upper limit of the combined speed is applied.
Set #2086 when using the external deceleration for each axis, and #2161 - #2165 when using the
external deceleration 2nd step or later.
This parameter is enabled when "#1239 set11/bit6" is set to "1".
---Setting range---
1 to 1000000(mm/min)
【#2163】 exdcax4 External deceleration speed 4
Set the upper limit of the feedrate when the external deceleration signal is ON and only one axis is
moved. In automatic operation, the upper limit of the combined speed is applied.
Set #2086 when using the external deceleration for each axis, and #2161 - #2165 when using the
external deceleration 2nd step or later.
This parameter is enabled when "#1239 set11/bit6" is set to "1".
---Setting range---
1 to 1000000(mm/min)
【#2164】 exdcax5 External deceleration speed 5
Set the upper limit of the feedrate when the external deceleration signal is ON and only one axis is
moved. In automatic operation, the upper limit of the combined speed is applied.
Set #2086 when using the external deceleration for each axis, and #2161 - #2165 when using the
external deceleration 2nd step or later.
This parameter is enabled when "#1239 set11/bit6" is set to "1".
---Setting range---
1 to 1000000(mm/min)
【#2165】 exdcax6 External deceleration speed 6
Set the upper limit of the feedrate when the external deceleration signal is ON and only one axis is
moved. In automatic operation, the upper limit of the combined speed is applied.
Set #2086 when using the external deceleration for each axis, and #2161 - #2165 when using the
external deceleration 2nd step or later.
This parameter is enabled when "#1239 set11/bit6" is set to "1".
---Setting range---
1 to 1000000(mm/min)
【#2179】 TapInpI In-position width for Tapping initial point
Set the in-position check width for synchronous tapping I point.
The value of "#2224 sv024" is applied when it is set "0".
* This parameter is enabled only when "#1223/bit3" and "#1245/bit0 or bit1" are "1".
---Setting range---
0 to 99.999 (mm)
246

Advertisement

Table of Contents
loading

Table of Contents