【#3038】 taps22 Synchronous tapping 2nd step rotation speed (Gear: 01)
Set the speed which switches from 2nd step to 3rd step in synchronous tapping multi-step
acceleration/deceleration control when gear 01 is selected.
The inclination of linear acceleration/deceleration control for 2nd step is determined by the ratio of
taps22(#3038) to tapt22(#3042).
When the inclination is not set for 3rd step or it is higher than that of 2nd step, the acceleration/
deceleration control is executed with the same inclination as the 2nd step for the rotation speed of
taps22 or higher.
---Setting range---
0 to 99999 (r/min)
【#3039】 taps23 Synchronous tapping 2nd step rotation speed (Gear: 10)
Set the speed which switches from 2nd step to 3rd step in synchronous tapping multi-step
acceleration/deceleration control when gear 10 is selected.
The inclination of linear acceleration/deceleration control for 2nd step is determined by the ratio of
taps23(#3039) to tapt23(#3043).
When the inclination is not set for 3rd step or it is higher than that of 2nd step, the acceleration/
deceleration control is executed with the same inclination as the 2nd step for the rotation speed of
taps23 or higher.
---Setting range---
0 to 99999 (r/min)
【#3040】 taps24 Synchronous tapping 2nd step rotation speed (Gear: 11)
Set the speed which switches from 2nd step to 3rd step in synchronous tapping multi-step
acceleration/deceleration control when gear 11 is selected.
The inclination of linear acceleration/deceleration control for 2nd step is determined by the ratio of
taps24(#3040) to tapt24(#3044).
When the inclination is not set for 3rd step or it is higher than that of 2nd step, the acceleration/
deceleration control is executed with the same inclination as the 2nd step for the rotation speed of
taps24 or higher.
---Setting range---
0 to 99999 (r/min)
【#3041】 tapt21 Synchronous tapping 2nd step acceleration/deceleration time constant
(Gear: 00)
Set the time constant for synchronous tapping 2nd step linear acceleration/deceleration control
when gear 00 is selected.
---Setting range---
1 to 5000 (ms)
【#3042】 tapt22 Synchronous tapping 2nd step acceleration/deceleration time constant 2
(Gear: 01)
Set the time constant for synchronous tapping 2nd step linear acceleration/deceleration control
when gear 01 is selected.
---Setting range---
1 to 5000 (ms)
【#3043】 tapt23 Synchronous tapping 2nd step acceleration/deceleration time constant
(Gear: 10)
Set the time constant for synchronous tapping 2nd step linear acceleration/deceleration control
when gear 10 is selected.
---Setting range---
1 to 5000 (ms)
C70 Setup Manual