Mitsubishi Electric C70 Setup Manual page 361

Hide thumbs Also See for C70:
Table of Contents

Advertisement

MITSUBISHI CNC
Appendix 1 Explanation of Parameters
【#29013(PR)】 Status Data:Bit Area Local Node Inform.
Status data: Bit area local node information area
Set a device to store the following data:
<1st word: Local node information area>
bit3: Operation data; indicates node switch of module.
0: Online / 1: Other than online
bit6: Setting data; indicates node No. switch of module.
0: Normal / 1: Error
bit7: Indicates module type.
0: QJ71FL71-F01(10BASE5,10BASE-T) / 1: QJ71FL71-B2-F01(10BASE2)
bit8: Indicates local node communication (token participation) status.
0: Normal / 1: Error
bitA: Local node CPU status 1; indicates local node Qn(H)CPU self-diagnosis result.
0: Normal / 1: Warning
bitB: Local node CPU status 2; indicates local node Qn(H)CPU self-diagnosis result.
0: Normal / 1: Error
<2nd word: Local node information area>
bit1: Indicates parameter setting status from Qn(H)CPU.
0: Setting complete / 1: Setting not complete
bit2: Indicates receive parameter data.
0: Normal / 1: Error
bit8: Indicates local node receive signal wait status (waiting for network participation).
0: No receive signal wait / 1: Receive signal wait
bit9: Indicates token transmission monitoring time out error status.
0: Normal / 1: Error
bitA: Indicates whether or not local node No. duplicates other node No.
0: Normal / 1: Duplicate node No. detected
bitB: Area 1 address multiplexing detection signal; indicates whether or not local node common
memory area 1 duplicates other node common memory area.
0: Normal / 1: Duplicate address detected
bitC: Area 2 address multiplexing detection signal; indicates whether or not local node common
memory area 2 duplicates other node common memory area.
0: Normal / 1: Duplicate address detected
bitD: Indicates the local node communication status during data linking participation.
0: Communication valid / 1: Communication invalid
---Setting range---
Within the number of device points set in the PC parameter's device setting.
【#29014(PR)】 Status Data:Word Area Specified Inform.
Status data: Word area instruct information area
Set a device to store the following data:
<1st word: Instruct information area>
Other node No. setting for parameter use:
Indicates node No. if reading the parameter/ join node data for other node.
1 to 254: Node No.
bit15 (top bit): Select the information to read. (0: Parameter / 1: Join node data)
<2nd word: Instruct information area>
Other node No. setting for device profile:
Indicates node No. if reading device profile for other node.
1 to 254: Node No.
<3rd word: Instruct information area>
Other node No. setting (1) for log information:
Indicates node No. if clearing log information for other node.
1 to 255: Node No.
<4th word: Instruct information area>
Other node No. setting (2) for log information:
Indicates node No. if reading log information for other node.
1 to 254: Node No.
---Setting range---
Within the number of device points set in the PC parameter's device setting.
344