【#29069(PR)】 Obstacle Status Module side Transfer Cont
Each node obstacle status read word count
Set a read word count of the data where the slave node communication error status is saved.
The standard setting is "4".
---Setting range---
1 to 4
【#29070(PR)】 Obstacle Status PLC side Device
Each node obstacle status read device
Set a device to store the following data:
Slave node communication obstacle status is stored.
When the corresponding node communication error information read is executed in the message
communication, the corresponding bit will be turned OFF.
Bit settings: 0: No obstacle information / 1: Obstacle information exists
<1st word>
bit0: 0th slave node
bit1: 1st slave node
:
bitF: 15th slave node
<2nd word>
bit0: 16th slave node
bit1: 17th slave node
:
bitF: 31st slave node
<3rd word>
bit0: 32nd slave node
bit1: 33rd slave node
:
bitF: 47th slave node
<4th word>
bit0: 48th slave node
bit1: 49th slave node
:
bitF: 63rd slave node
---Setting range---
Within the number of device points set in the PC parameter's device setting.
【#29071(PR)】 Down Node Detect. Disable St. Module side Transfer Cont
Down node detection read word count
Set a read word count of the data where the down node detection disabled status is saved.
The standard setting is "4".
---Setting range---
1 to 4