Appendix 1 Explanation of Parameters
【#13227】 SP227 SFNC7 Spindle function 7
Select the spindle functions.
Functions are allocated to each bit.
Set this in hexadecimal format.
bit F-C : dis Digital signal input selection
0: No signal
1: SLS (Safely Limited Speed) function door state signal
4: Proximity switch signal detection
Other settings: setting prohibited
bit B-A : dos3 Digital signal output 3 selection (MDS-DJ-SP)
bitB,A=
00: Disable
01: Setting prohibited
10: Contactor control signal output
11: Setting prohibited
bit 9-3 :
Not used. Set to "0".
bit 2 : ccu Lost motion/overshoot compensation compensation amount setting unit
0: Short-time rated %
bit 1-0 :
Not used. Set to "0".
【#13228】 SP228 SFNC8 Spindle function 8
Not used. Set to "0000".
336
1: Short-time rated 0.01%
ccu
dos3