【#2032】 nochk Whether reference position return is completed not checked
Select whether to check the reference position return completion.
0: Check the reference position return completion.
1: Not check the reference position return completion.
When "1" is set, the absolute and incremental commands can be executed even if dog type (or Z
phase pulse system) reference position return is not completed.
Note that this setting is available for a rotary axis only.
【#2037】 G53ofs Reference position #1
Set the position of the first reference position from the zero point of the basic machine coordinate.
Reference position #3
---Setting range---
-99999.999 to 99999.999 (mm)
【#2038】 #2_rfp Reference position #2
Set the position of the second reference position from the zero point of the basic machine
coordinate.
Reference position #3
---Setting range---
-99999.999 to 99999.999 (mm)
Basic machine coordinate
Reference position #1
(#2037 G53ofs)
Reference position #2
(#2038 #2_rfp)
(#2039 #3_rfp)
Basic machine coordinate
Reference position #1
(#2037 G53ofs)
Reference position #2
(#2038 #2_rfp)
(#2039 #3_rfp)
Appendix 1.4 Axis Specifications Parameters
Reference position #4
(#2040 #4_rfp)
Reference position #4
(#2040 #4_rfp)