MITSUBISHI CNC
2 GOT Initial Setup
(3) The "System Environment" dialog box now displays "Communication Settings".
Confirm "Use Communication Settings" is checked, and select the following items of the standard I/F setting from
among the pull-down menu.
Standard I/F-4
CH No.: 1
Driver: By setting "1" to "Ethernet (MELSEC), Q17nNC, CRnD-700 (CH No.)", the driver will be
automatically set. )
Then click "Detail Setting...".
(4) Set the following values in the "Communication Detail Settings" dialog box.
GOT NET No.: 1
GOT PC No.: 1
GOT IP Address: GOT's own IP address (Example: 192.168.1.1)
After setting, click "OK" to confirm the setting values.
32