Aspirenet Ip - NEC Univerge SV9100 Manual

Hide thumbs Also See for Univerge SV9100:
Table of Contents

Advertisement

Issue 2.0
03
°
10-03-10 : PCB Setup - Master/Slave System
Determine which system will be the master system and which one(s) will be the slave system(s). If one end of
the line is set as the Master, the other end of the line must be set as the Slave. The choice of Master/Slave is
determined by the ISDN clock available at the SV9100 System, see the Section 5 for further detail.
Item
No.
10
°
10-03-11 : PCB Setup - Networking System Number
The Networking ID is used to select the access route for dialed digits. You can choose any number 0 to 50 (0
equals no operation). This ID is used when setting the numbering plan for the networked systems. The same ID
number must be set in both 10-03-11 and 11-01. Refer to
the numbering plan settings.
Item
No.
10
2.3

AspireNet IP

CAUTION
SV9100 Networking Manual
Connection Type
0 = Point-to-Multipoint (not available for
Networking)
1 = Point-to-Point
Example:
System – A
1: Point-to-Point
ISDN Line Number
Item
Master/Slave System
(Network Mode Only)
Example:
System – A
1: Master
ISDN Line Number
Item
Networking System Number (Net-
work Mode Only)
Example:
System – A
Networking ID: 1
As with any Voice Over IP (VoIP) implementation, there are several
issues that should be considered when setting up AspireNet IP
System – B
1: Point-to-Point
1-4
Input Data
0- Slave System
1- Master System
System – B
2: Slave
2.5 Numbering Plan in on page -12
1-4
Input Data
0-50
System – B
Networking ID: 1
0
Default
0
for more on
Default
0
13-7

Advertisement

Table of Contents
loading

Table of Contents