NEC Univerge SV9100 Manual page 566

Hide thumbs Also See for Univerge SV9100:
Table of Contents

Advertisement

Issue 2.0
51-16 : NetLink System Data Replication Mode Setting
Level:
IN
Description
Use Program 51-16: NetLink System Data Replication Mode Setting to set the
system data replication between the Primary and Secondary systems.
Input Data
Item
No.
01
02
03
04
05
06
.
IMPORTANT
SV9100 Networking Manual
Item
System Data Replication Mode
Set the synchronous mode of the system data.
When set to 1, the systems are synchronized at
the time set in Item 02 below.
When set to 2, the systems are synchronized at
regular time intervals set in Item 03 below.
System Data Replication Time Setting
Set the time of day that both systems
synchronize database (when Item 01 is set to 1.)
System Data Replication Interval Setting
Set the time interval that both systems
synchronize database (when Item 01 is set to 2).
Replication Time Stamp
Show next replication time. (Read-Only)
System Data Replication Wait Time
Set the wait time until replication starts when
NetLink is created.
System Data Replication Interval
Set time to start replication to the next node after
replication to one node is completed.
In a NetLink system with In-Mail, replication should be scheduled during
non-peak hours of operation
Program 51 : NetLink Service
Input Data
0 = Disable
1 = Setting Time Mode
2 = Interval Mode
0000~2359
15~1440 (minutes)
Month: 0~12
Day: 0~31
Hour: 00~23
Minute: 00~59
1~86400 (seconds)
0~86400 (seconds)
Default
0
0200
30 (min)
180 sec
1 sec
10-79

Advertisement

Table of Contents
loading

Table of Contents