Issue 2.0
Program 10 : System Configuration Setup
10-27 : H.323 System Interconnection with Application Setup
Level:
SA
Description
Use Program 10-27 : H.323 Interconnection with Application Setup to set the IP address of the
networked IP systems.
Input Data
Input Data
Item
No.
01
IP Address
System ID is related with the
System ID in the Numbering Plan
(Program 11-01-03). When the
digits are analyzed and the
system ID is determined from the
SV9100 data set in the
Numbering Plan, the networking
call will be sent to the IP Address
set in this program.
The IP Address should be the IP
Address of the peer CPU
(Program 10-12-01)
02
Call Procedure Port
The Port Number should be set
with the same value as the H.225
setup port in Program 84-02-33.
Conditions
None
Feature Cross Reference
None
SV9100 Networking Manual
System ID
Item
1.0.0.1_126.255.255.254
128.1.0.1 _191.254.255.254
192.0.1.1 _223.255.254.254
1-65535
01-50
Input Data
Default
0.0.0.0
1730
Default
11-01-01
10-12-01
84-02-33
13-77