Description
Use Program 14-01 : Basic Trunk Data Setup to set the basic options for each trunk port. Refer to the
chart below for a description of each option, its range and default setting.
Input Data
Item
No.
01
Trunk Name
Set the names for
trunks. The trunk
name displays on a
multiline terminal for
incoming and
outgoing calls.
02
Transmit Level
Use this option to
select the CODEC
gain for the trunk. The
option sets the gain
(signal amplification)
for the trunk you are
programming.
03
Receive Level
Use this option to
select the CODEC
gain for the trunk. The
option sets the gain
(signal amplification)
for the trunk you are
programming.
SV9100 Networking Manual
Program 14 : Trunk, Basic Setup
Trunk Port Number
Item
Input Data
Up to 12 Characters
1~63
(-15.5dB~
+15.5dB in 0.5dB
intervals)
1~63
(-15.5dB ~ +15.5dB
in 0.5dB intervals)
14-01 : Basic Trunk Data Setup
001~400
Default
Line 001
Line 002
Line 003
:
Line 400
32 (0dB)
32 (0dB)
Related
Program
13-105