Program
Program Name
Number
84-10-XX
ToS Setup
DT800/DT700
Multiline Logon
84-22-01
Information Setup –
User ID
DT800/DT700
Multiline Logon
84-22-02
Information Setup –
Password
DT800/DT700
Multiline Logon
84-22-03
Information Setup –
User ID Omission
DT800/DT700
Multiline Logon
84-22-04
Information Setup –
Log Off
DT800/DT700
Multiline Logon
84-22-05
Information Setup –
Nickname
DT800/DT700
Multiline Basic
84-23-01
Information Setup –
Registration Expire
Timer
DT800/DT700
Multiline Basic
84-23-02
Information Setup –
Subscribe Expire
Timer
8-56
Description/Comments
Assignments deal with setting of the
Layer 3 IP Header ToS field as it
leaves the VoIPDB unit.
Specify the protocol to assign the
ToS field for, and select the
populated field to conform to either
IP Precedence or Differentiated
Services.
When setting IP Precedence, assign
Priority, Delay, Throughput, and
Reliability in Programs 84-10-01/02/
03/04/05.
When setting DiffServ, only assign
the DSCP in Program 84-10-07.
User ID for Manual or Auto
registration (Program 10-46-01).
Password for Manual or Auto
registration (Program 10-46-01).
When set to manual login mode, the
user ID is omitted from the display
during entry by the user.
Allow the ability to log off from the IP
terminal when using manual
registration mode.
At half the value of this timer the IP
terminal sends another registration
message to the CPU.
At half the value of this timer the IP
terminal sends another Subscribe
message to the CPU.
Assigned Data
Protocol Type
1 = Not Used
2 = Not Used
3 = Voice Control
4 = H.323
5 = RTP/RTCP
6 = SIP
7 = CCISoIP
8 = SIP MLT
9 = SIP Trunk
10 = NetLink
11 = Video RTP/RTCP
Assign up to 32 Alpha/
Numeric Characters
Default is No Setting
Assign up to 16 Alpha/
Numeric Characters
Default is No Setting
0 = Off
1 = On
Default is 0
0 = Off
1 = On
Default is 1
Assign up to 32 Alpha/
Numeric Characters
Default is No Setting
Range: 60~65535 Sec.
Default is 180
Range: 60~65535 Sec.
Default is 3600