Program 21-05 : Toll Restriction Class
Input Data
Toll Restriction Class Number
Item
Item
No.
01
International Call
Restriction Table
02
International Call
Permit Code Table
03
--- Not Used ---
04
Maximum Number of
Digits Table
Assignment
05
Common Permit
Code Table
06
Common Restriction

Table

2-336
Program 21 : Outgoing Call Setup
to set the system Toll Restriction classes (1~15).
Input Data
Default
0 = Unassigned
1, 6~15 = 0
(No)
2~5 = 1
1 = Assigned
(Yes)
0 = Unassigned
1, 3~15 = 0
(No)
2 = 1
1 = Assigned
(Yes)
1~4 = Table
1, 2, 6~15 = 0
0 = Disable
3 = 1
(None)
4 = 2
5 = 3
0 = Unassigned
1, 8~15 = 0
(No)
2~7 = 1
1 = Assigned
(Yes)
0 = Unassigned
1, 6~15 = 0
(No)
2~5 = 1
1 = Assigned
(Yes)

21-05 : Toll Restriction Class

1~15
Description
Assign/Unassign the
International Call Restrict Table
for the Toll Restriction Class you
are programming. Enter
International Call Restrict Table
data in Program 21-06-01.
Assign/Unassign the
International Call Permit Table
for the Toll Restriction Class you
are programming. Enter
International Call Permit Table
data in Program 21-06-02.
Select the table (defined in
21-06-03) to be used to
determine the maximum number
of digits allowed for outgoing
calls.
Choose whether the table set up
by 21-06-04 is referred to or not.
Choose whether the table set up
by 21-06-05 is referred to or not.
Program 21 : Outgoing Call Setup
Issue 4.0
Related
Program
21-06-01
21-06-02
21-06-03
21-06-04
21-06-05