Input Data (Continued)
Item
Name
52
Receive HookFlash Duration
Min. Time (E&M)
53
Receive HookFlash Duration
Max. Time (E&M)
54
Receive HookFlash Duration
Min. Time (OPX)
55
Receive HookFlash Duration
Max. Time (OPX)
56
Loop Off Guard Time (Loop)
57
Loop Off Guard Time (Ground)
58
Loop Off Guard Time (DID)
59
Loop Off Guard Time (E&M)
60
Loop Off Guard Time (OPX)
61
Double Ringing Send Time 1
(OPX)
62
Double Between Ringing Send
Time 1 (OPX)
63
Double Ringing Send Time 2
(OPX)
64
Double Between Ringing Send
Time 2 (OPX)
65
Single Ringing Send Time (OPX)
66
Receive DP Make Max. Time
(ALL)
67
Receive DP Break Min. Time
(ALL)
68
Receive DP Break Max. Time
ALL)
69
Single Between Ringing Send
Time (OPX)
70
Guard Time 1 (Loop)
2-712
Input Data
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
Program 81 : Basic Hardware Setup for Trunk
Issue 4.0
Default
3
300ms
6
600ms
3
300ms
6
600ms
20
2000ms
20
2000ms
20
2000ms
20
2000ms
20
2000ms
5
500ms
5
500ms
25
2500ms
30
3000ms
10
1000ms
9
900ms
9
900ms
9
900ms
9
900ms
9
900ms

Advertisement