T1 Trunk Timer Setup - NEC univerge SV9100 Programming Manual

Hide thumbs Also See for univerge SV9100:
Table of Contents

Advertisement

Issue 4.0
Program 81 : Basic Hardware Setup for Trunk
Level:
IN
Description
Use Program 81-08 : T1 Trunk Timer Setup to define the basic timer setting of each T1 Trunk type.
Input Data
Item
Name
01
Answer Signal Detection Time
(Loop)
02
Answer Signal Detection Time
(Ground)
03
Answer Signal Detection Time
(DID)
04
Answer Signal Detection Time
(E&M)
05
Answer Signal Detection Time
(OPX)
06
Clear Signal Detection Time
(Loop)
07
Clear Signal Detection Time
(Ground)
08
Clear Signal Detection Time
(DID)
09
Clear Signal Detection Time
(E&M)
10
Clear Signal Detection Time
(OPX)
11
Ringing Signal Detection Time
(Loop)
12
Ringing Signal Detection Time
(Ground)
13
Ringing Signal Detection Time
(DID)
SV9100 Programming Manual

81-08 : T1 Trunk Timer Setup

Input Data
1~250
(4ms ~ 1000ms)
1~250
(4ms ~ 1000ms)
1~250
(4ms ~ 1000ms)
1~250
(4ms ~ 1000ms)
1~250
(4ms ~ 1000ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~250
(8ms ~ 2000ms)
1~250
(8ms ~ 2000ms)
1~250
(8ms ~ 2000ms)
Default
15
60ms
15
60ms
15
60ms
15
60ms
15
60ms
6
600ms
6
600ms
6
600ms
6
600ms
6
600ms
10
80ms
10
80ms
10
80ms