NEC univerge SV9100 Programming Manual page 866

Hide thumbs Also See for univerge SV9100:
Table of Contents

Advertisement

Alarm
Type
Report
No.
6
0
0
Blocking
7
1
0
Power failure
8
1
0
RAM Backup
Battery Error
9
--- Reserved ---
10
0
0
ISDN Link
Error
11
0
0
CTI Link Error
2-826
Name
Content of Alarm
The link of terminals
connected with the ESI
package came off.
The supply of the
commercial power
stopped.
RAM backup battery on the
GCD-CP10 blade is
unplugged or defective.
Layer1 link of ISDN lines
came off.
The link with the CTI server
came off.
Cause
Action
1. Terminal
1. Confirm the terminal
breakdown.
connected with
same ESI. If they
work normally,
2 Faulty wiring and
confirm the
wiring
breakdown or the
termination.
wiring for the
terminal.
3. External noise.
2. Exchange the
terminal that doesn't
4. ESI package
work and the
Breakdown.
working terminal,
and confirm it's
working. An external
factor of the noise
etc. is thought.
3. Confirm wiring and
the installation,etc.
4.Check with
manufacturer if the
problem occurs
again.
1. The power cable
1. Confirm the power
came off.
supply outlet when
the commercial
power has not
2. Power failure
stopped.
3. The power
2. Check with the
supply broke
manufacturer if the
down.
problem occurs
again.
Check the battery
connector. If it is
connected correctly,
replace the battery.
1. Check
1. Confirm the data of
connection
PRG10-03.
between main
device and ISDN
2. Confirm wiring and
line.
installation of DSU.
2. DSU breakdown
3. Check with the
manufacturer if the
3. The setting of
problem occurs
PRG10-03 does
again.
not correspond
to an actual line.
1. LAN cable
1. Confirm the CTI
defective.
server, wiring, and
the connection.
2. Connected HUB
broken.
2. Check with
manufacturer if the
problem occurs
3. The CTI server
again.
doesn't start
normally.
Program 90 : Maintenance Program
Issue 4.0
Alarm
Recovery
Status
The error is
ERR
recovered
REC
when
connecting or
exchanging it.
When the
ERR
commercial
REC
power is
restored, the
error is
recovered.
The error is
ERR
recovered
REC
once the
battery is
replaced.
When the
ERR
connection
REC
returns
normally, the
error is
recovered.
When the
ERR
connection
REC
returns
normally, the
error is
recovered.