Issue 4.0
Level:
IN
Description
Use Program 22-03 : Trunk Ring Tone Range to select the ring tone range for the trunk. The trunk
uses a ring tone in the range selected when it rings an extension. Eight ring tones are available.
Customize the Trunk Ring Tones in Program 82-01.
Input Data
Trunk Port Number
Item
Ring Tone Pattern
No.
01
0~3 = Tone Pattern 1~4
4~8 = Melody 1~5
9~12 = Tone Pattern 5~8
Table 2-8 Program 22-03 – Incoming Signal Frequency Patterns
Incoming Signal
Frequency Pattern
Pattern 1
Pattern 2
Pattern 3
Pattern 4
Pattern 5
SV9100 Programming Manual
Program 22 : Incoming Call Setup
Default
0
Select the ring tone range for the trunk.
The trunk uses a ring tone in the range
selected when it rings an extension.
Eight ring tones are available.
Type
Frequency 1
High
1100Hz
Middle
660Hz
Low
520Hz
High
1100Hz
Middle
660Hz
Low
520Hz
High
2000Hz
Middle
1400Hz
Low
1100Hz
High
2000Hz
Middle
1400Hz
Low
1100Hz
High
1400Hz
Middle
760Hz
Low
660Hz
22-03 : Trunk Ring Tone Range
001~400
Description
Frequency 2
Modulation
1400Hz
760Hz
660Hz
1400Hz
760Hz
660Hz
760Hz
660Hz
540Hz
760Hz
660Hz
540Hz
540Hz
540Hz
540Hz
Related
Program
15-02
16Hz
16Hz
16Hz
8Hz
8Hz
8Hz
16Hz
16Hz
16Hz
8Hz
8Hz
8Hz
16Hz
16Hz
16Hz
2-363