Issue 4.0
Level:
MF
Description
Use Program 20-66 : STUN/TURN Server Setting to set the STUN/TURN Server parameters.
Input Data
Item
No.
01
Server Type
Define the Server type as Disable, STUN or TURN
02
IP Address / Server Name
Define the IP Address or Server Name
03
Port Number
Define the port number of the Server
04
Authentication Name
Set the authentication name if the server needs authentication, otherwise
leave blank.
05
Password
Set the Password if the server needs authentication, otherwise leave
blank
Conditions
None
Feature Cross Reference
None
SV9100 Programming Manual
Program 20 : System Option Setup
20-66 : STUN/TURN Server Setting
Item
Input Data
0 = Disable
1 = STUN
2 = TURN
Max. 128 characters
No Setting
0 ~ 65535
Max. 32 characters
No Setting
Max. 32 characters
No Setting
Default
0
3478