Level:
IN
Description
Use Program 30-02 : DSS Console Extension Assignment to identify which extensions have DSS
Consoles connected.
Up to 32 different extensions with DSS Consoles can be set up. A single extension can have up to four
60-button DSS Consoles (32 is the maximum allowed per system).
When programming, each extension/DSS Console(s) combination is called a Console Number. There
are 32 Console Numbers (1~32). Console Numbers can be assigned to extensions. When entering data,
the assignment for Console Number 1 is normally made first.
Input Data
60-button DSS Console Number
Item
No.
01
Extension Number
Enter the extension number for the multiline terminal connected with the DSS
console (up to eight digits).
Conditions
None
Feature Cross Reference
Direct Station Selection (DSS) Console
2-442
Program 30 : DSS/DLS Console Setup
30-02 : DSS Console Extension Assignment
Item
01~32
Default
No Setting
Program 30 : DSS/DLS Console Setup
Issue 4.0