IN
Description
Use Program 90-10 : System Alarm Setup to assign a status to system alarms. You can designate an
alarm as Major or Minor. This program also assigns whether or not the alarm information is reported to
the predefined destination.
Input Data
Alarm Number
Item
Item
No.
01
Alarm Type
02
Report
Alarm
Type
Report
No.
1
2
0
PKG Initialize
Error.
2
2
0
PKG
Mounting
Error
2-824
Program 90 : Maintenance Program
001~100
Input Data
0 = Not Set
1 = Major Alarm
2 = Minor Alarm
0 = Not Report (No autodial)
1 = Report (autodial)
Name
Content of Alarm
1. The PKG failed to
initialize.
2. The PKG did not start
normally.
The unit did not step on a
regular procedure and it
was pulled out. Or, it is not
normally inserted.

90-10 : System Alarm Setup

Cause
Action
1. PKG not inserted
1. Insert PKG firmly.
firmly.
2. Insert PKG firmly.
2. PKG was
3. Delete slot
removed, but not
information in
reinserted firmly.
PRG 90-05 and
3. Old PKG data
insert the PKG
still reported due
again.
to no
initialization.
1. The package is
1. Insert the package
not completely
firmly.
inserted.
2. Try again after
2. The package is
initializing the
out of order.
system data once
when LED doesn't
blink normally.
3. Exchange packages.
Program 90 : Maintenance Program
Issue 4.0
Alarm
Recovery
Status
During
ERR
initialization,
REC
the PKG is
recognized.
When unit is
ERR
reconfirmed,
REC
the error is
recovered.