Alarm
Type
Report
No.
3
2
0
Connection
fault between
GCD-CP10
and other
PKGs.
4
2
0
PKG S/W
Download
Error
5
1
0
Cooling fan
error
SV9100 Programming Manual
Name
Content of Alarm
The error occurred when
communicating with the
package. When the
package is broken, it
recognizes it as a
communication fault.
The unit program could not
be downloaded normally.
The unit could not be
started normally.
The cooling fan does not
work normally.
Cause
Action
1. The unit is not
1. Insert the unit firmly.
completely
installed.
2. The power-supply
voltage must use
2. The power-
another power
supply voltage
supply when is in the
of the system is
range of ratings or
outside ratings.
measuring with the
voltmeter, and
deviating from the
3. The equipment
rated range.
that generates
the noise in the
same power
3. Use the power
supply system
supply besides the
as the power
equipment with the
supply origin of
possibility of the
the system is
noise source.
connected, and
it malfunctions
4. Separate as much
because of the
as possible and use
power supply
a main device from
noise.
the equipment by
which you seem
4. The equipment
may generate the
to which it is
radiation noise.
adjacent to of a
main device,
5. Ground the chassis
and has put out
correctly.
the radiation
noise exists,
and it
malfunctions
because of the
radiation noise.
5. The chassis is
not properly
grounded.
1. The package
1. Delete slot
software is not
information that
stored in the
corresponds by
downloaded
PRG90-05-01 to
USB memory.
delete package
information that was
installed before.
2. The stored
package
software is
2. There is a possibility
illegal.
that the unit program
Package
is broken though an
information that
external factor of the
was installed
noise etc.
before remains.
3. load into the USB
memory and try
again when you
back up the unit
program.
4. Check with maker on
uncertain points.
1. The cooling fan
1. Confirm the cooling
has stopped
fan is turning.
working.
2. Verify the cooling fan
2. The cooling fan
mounting.
has come off.
Alarm
Recovery
Status
When unit is
ERR
confirmed, the
REC
error is
recovered.
Please
ERR
exchange
REC
units, though it
is likely to
restore by
mounting the
unit again.
When the unit
program is
normally
downloaded,
the error is
recovered.
Replace the
cooling fan if it
is defective.