Program 81 : Basic Hardware Setup For Trunk; Cot Initial Data Setup - NEC univerge SV9100 Programming Manual

Hide thumbs Also See for univerge SV9100:
Table of Contents

Advertisement

Program 81 : Basic Hardware Setup for Trunk

Level:
MF
Description
Use Program 81-01 : COT Initial Data Setup to define the various basic data parameters for the COT
(CO blade) Unit.
Input Data
Item
No.
01
PCM Encoding Method
Specification
02
Loop Current Detection Time
03
Clear Signal (Open Loop)
Detection Time
This is the loop start trunk disconnect
recognition timer.
04
Ringing Signal Detection Minimum
Time
05
Single Ringing Detection Minimum
Time
06
Double Ringing Detection
Minimum Off Time
07
Double Ringing Detection
Maximum Off Time
08
Ringing Signal not Detection
Minimum
09
Time Ringing Signal Stop
Detection Time
10
Continuous Ringing Minimum
Time
11
Continuous Ringing Maximum
Time
12
Caller ID Detection Time
SV9100 Programming Manual
Item
Input Data
(8~2040ms)
(8~2040ms)
(8~2040ms)
(0,8~2040ms)
(0,8~2040ms)
(0,8~2040ms)
(8~2040ms)
(64~16320ms)
(0,8~2040ms)
(0,8~2040ms)
(0~16320ms)
Program:

81-01 : COT Initial Data Setup

Default
0 = -law
0
1 = A-law
1~255
75
(600ms)
1~255
38
(304ms)
1~255
13
(104ms)
0~255
82
(656ms)
0~255
13
(104ms)
0~255
50
(400ms)
1~255
88
(704ms)
1~255
94
(6016ms)
0~255
38
(304ms)
0-255
88
(704ms)
0~255
0
(0ms)
81
2-697

Advertisement

Table of Contents
loading

Table of Contents