Program 81 : Basic Hardware Setup for Trunk
Level:
MF
Description
Use Program 81-02 : DIOPU Initial Data Setup to define the various basic timers for the DID Unit.
Input Data
Item
01
PCM Method Type
02
Answer Signal Time
03
Clear Signal (Open Loop) Detection Time
04
Ringing Signal Detection Minimum Time
05
Hook Flash Time
06
Pause Time
07
WINK/DELAY Duration Time
08
Incoming-WINK/DELAY Send Time
09
Seizure-WINK/DELAY Receive Max. Time
10
Receive WINK/DELAY Duration Min. Time
11
Receive WINK/DELAY Duration Max. Time
12
Receive DP Make Minimum Time
13
Receive DP Make Maximum Time
2-700
Name

81-02 : DIOPU Initial Data Setup

Input Data
0 = -law
1= A-law
1~255
(10~2550ms)
1~255
(100~25500ms)
1~255
(10~2550ms)
1~255
(8~2040ms)
1~255
(32~8160ms)
1~255
(10~2550ms)
1~255
(100~25500ms)
1~255
(100~25500ms)
1~255
(10~2550ms)
1~255
(10~2550ms)
1~255
(2~510ms)
1~255
(2~510ms)
Program 81 : Basic Hardware Setup for Trunk
Issue 4.0
Default
0
6
(60ms)
7
(700ms)
10
(100ms)
25
(200ms)
94
(3008ms)
20
(200ms)
3
(300ms)
48
(4800ms)
13
(130ms)
31
(310ms)
5
(10ms)
50
(100ms)

Advertisement