Service counter

The Service counter function supervises the
BRAKE OPT COUNTS. The two signals can be monitored for the calculation of the
overall crane operation time and the brake open counts. The brake open counts can
be reset using the parameter
time can be reset using the parameter

Settings

Parameter
79.01
79.02

Diagnostics

Actual signals
01.43
02.28

Adaptive Programming using the function blocks

Conventionally, you can control the operation of the drive with parameters. Each
parameter has a fixed set of choices or a setting range. The parameters make the
programming easy, but the choices are limited. You cannot customise the operation
any further. The Adaptive Program (AP) makes free customising possible without the
need of a special programming tool or language:
• The program is built of standard function blocks included in the drive application
program.
• The control panel is the programming tool.
• You can document the program by drawing it on block diagram template sheets.
The maximum size of the Adaptive Program is 15 function blocks. The program may
consist of several separate functions. For more information, see the Application
Guide for Adaptive Program (3AFE64527274 [English]).
For examples of Adaptive Programming (AP) and creating AP files for new features,
see
Note: If you use and/or change the AP blocks used in the Crane control program
made by ABB, you are responsible for the software and the application.

DriveAP

DriveAP is a Windows-based tool for Adaptive Programming. With DriveAP it is
possible to upload the Adaptive Program from the drive and edit it with PC.
For more information, see DriveAP User's Manual (3AFE64540998 [English]).
Program features
Additional information
Reset brake operation counts
Reset crane operation time
Additional information
Crane operation time
Number of brake open counts
Adaptive Programming examples for crane control
01.43
79.01
BRAKE CTR RESET and the crane operation
79.02
RESET OPT TIME.
CRANE OPT TIME and the
on page 297.
02.28