60

Programmable analogue inputs

The drive has three programmable analogue inputs: one voltage input (0/2 to 10 V or
-10 to 10 V) and two current inputs (0/4 to 20 mA). Two extra inputs are available if
an optional analogue I/O extension module is used. Each input can be inverted and
filtered, and the maximum and minimum values can be adjusted.
The Crane control program supports unipolar and bipolar joystick configuration:
• Unipolar (AI1/JOYST), 0 ... 10 V for the reference and digital inputs for the sign
and start (for example, DIF, DI2 R)
• Bipolar (AI1 BIPOLAR), -10 ... +10 V for the sign and reference and one digital
input for main start (for example, DI1).

Update cycles in the Crane control program

Input
AI / standard
AI / extension
1)
Update cycle in the motor temperature measurement function. See group

Settings

Parameter
Group
SELECT
Group
INPUTS
30.01
35.01
42.07
98.06
98.13
98.14

Diagnostics

Actual signal
01.18, 01.19,
01.38,
Group
SIGNALS
Program features
Cycle
6 ms
6 ms (100 ms
Additional information
11 REFERENCE
AI as a reference source
13 ANALOGUE
Processing of the standard inputs
Supervision of AI loss
AI in a motor temperature measurement
AI in a mechanical brake control function
Activation of optional analogue inputs
Optional AI signal type definition (bipolar or unipolar)
Optional AI signal type definition (bipolar or unipolar)
Additional information
01.20
Values of standard inputs
01.39
Value of optional inputs
09 ACTUAL
Scaled analogue input values (integer values for function block
programming)
1)
)
35 MOT TEMP
MEAS.