Rdio-01 Digital I/O Extension; Control Using Step Reference - ABB ACS800 Firmware Manual

Crane control program
Hide thumbs Also See for ACS800:
Table of Contents

Advertisement

RDIO-01 digital I/O extension

1)
Considering the function pointer is
configured with an inverted signal
*
To be configured using respective
pointer parameters

Control using step reference

Name
Description
Start/Stop Control
Selecting the source for start and stop signals of the
two external control locations, EXT1 and EXT2
for EXT1
Selecting between EXT1 and EXT2
Defining Start/Stop selection
Defining the direction control
Selecting the DI for Slowdown
Selecting the signal for Fast Stop
Selecting the signal for the High-end limit
Selecting the signal for Low-end limit
Selecting the Step reference
Referencing
Setting Step references
Setting the speed (frequency) limits
Setting the Slowdown reference
Setting acceleration and deceleration times
24 - 230 V AC
N
X11
1
2
X12
1
2
3
4
DI1A
High-end limit (0 = Emergency stop)
DI1B
High-end limit
DI2A
Low-end limit (0 = Emergency stop)
DI2B
Low-end limit
DI3A
Fast Stop (0= Fast Stop active)
DI3B
Fast Stop
Set parameters
11.02
10.01
10.03
10.09
10.10
10.12
10.13
12.01
12.02
12.03
12.04
12.05
20.02, 20.01, (20.08,
20.07)
11.12
22.02, 22.03, 22.10
Application macros, control location EXT1/EXT2
143
1) *
1) *
1)
Parameter value
EXT 1
DI1 F, DI2 R
REQUEST
DI4
DI9,DI10,DI11

Advertisement

Table of Contents
loading