Motor Model - ABB ACS800 Firmware Manual

Crane control program
Hide thumbs Also See for ACS800:
Table of Contents

Advertisement

Index
Name/Selection
96.06
EXT AO2 PTR
-255.255.31 ...
+255.255.31 / C.-
32768 ... C.32767
96.07
INVERT EXT AO2
NO
YES
96.08
MINIMUM EXT AO2
0 mA
4 mA
10 mA
12 mA
96.09
FILTER EXT AO2
0.00 ... 10.00 s
96.10
SCALE EXT AO2
10 ... 1000%

97 MOTOR MODEL

97.12
EM STOP DIO
NO
RDIO-SLOT1
RDIO-SLOT2
RDIO-DDCS
97.16
SPD CORR PTR
-255.255.31 ...
+255.255.31 / C.-
32768 ... C.32767
97.17
APL LIM WRN MASK Application limit warning mask. Default 0000 0001 1111 1000 b (binary mode).
Description
Defines the source or constant for value.
Parameter index or a constant value. See parameter
the difference.
Activates the inversion of analogue output AO2 of the analogue I/O extension
module. The analogue signal is at its minimum level when the drive signal
indicated is at its maximum and vice versa.
Inactive
Active
Defines the minimum value for analogue output AO2 of the analogue I/O
extension module. See parameter 96.03.
0 mA
4 mA
10 mA
12 mA
Defines the filtering time constant for analogue output AO2 of the analogue I/O
extension module. See parameter 15.04.
Filtering time constant
Defines the scaling factor for analogue output AO2 of the analogue I/O
extension module. See parameter 15.05.
Scaling factor
Enables emergency stop commands through the RDIO module located on the
RMIO board (RDIO-SLOT1 or RDIO-SLOT2) or in the external I/O Module
Adapter AIMA (RDIO-DDCS).
- RDIO digital input 1 (DI1) = OFF2 STOP
- RDIO digital input 2 (DI2) = OFF3 STOP
The OFF3 deceleration time is defined by parameter
TIME.
Emergency stop through the RDIO module is not in use.
OFF2 STOP (through DI1) and/or OFF3 STOP (through DI2) is taken from the
RDIO module located in option SLOT 1.
OFF2 STOP (through DI1) and/or OFF3 STOP (through DI2) is taken from the
RDIO module located in option SLOT 2.
OFF2 STOP (through DI1) and/or OFF3 STOP (through DI2) is taken from the
RDIO module located on the AIMA I/O Module Adapter (RDIO-DDCS).
Note: If RDIO-DDCS is selected, the module node number must be set to 7.
Speed correction pointer. Default: +.000.000.00. Defines external speed
correction by writing it to signal SPEED CORR BUFF (03.35). Speed correction
pointer is to be used only when Synchro control is not used.
Parameter index or a constant value.
This parameter can block application messages not required for the control
panel display.
10.04
for information on
22.07
EM STOP RAMP
Actual signals and parameters
219
FbEq
1000 =
1 mA
-
0
65535
1
2
3
4
0 ... 1000
100 ...
10000
1
2
3
4