Rdio-01 Digital I/O Extension Module -1; Rdio-01 Digital I/O Extension Module -2 - ABB ACS800 Firmware Manual

Crane control program
Hide thumbs Also See for ACS800:
Table of Contents

Advertisement

RDIO-01 digital I/O extension module -1

1)
Considering the function pointer is
configured with an inverted signal
*
To be configured using respective
pointer parameters

RDIO-01 digital I/O extension module -2

24 - 230 V AC
N
X11
1
2
X12
1
2
3
4
24 - 230 V AC
N
X11
1
2
X12
1
2
3
4
DI1A
High-end limit (0 = Emergency stop)
DI1B
High-end limit
DI2A
Low-end limit (0 = Emergency stop)
DI2B
Low-end limit
DI3A
Step reference DI
DI3B
DI1A
Step reference DI
DI1B
DI2A
Step reference DI
DI2B
DI3A
DI3B
Application macros, control location EXT1/EXT2
145
1) *