Limits - ABB ACS800 Firmware Manual

Crane control program
Hide thumbs Also See for ACS800:
Table of Contents

Advertisement

174
Index
Name/Selection
16.07
PARAMETER SAVE
DONE
SAVE..
16.08
RUN ENA PTR
-255.255.31 ...
+255.255.31 / C.-
32768 ... C.32767
16.09
CTRL BOARD
SUPPLY
INTERNAL 24V
EXTERNAL 24V
16.11
FAULT RESET PTR
-255.255.31 ...
+255.255.31 / C.-
32768 ... C.32767
16.12
POWER ON RESET
TD
0 ... 60 s
16.13
USER MACRO PTR
-255.255.31 ...
+255.255.31 / C.-
32768 ... C.32767
16.14
FAN KWH CNT
RESET
NOT SEL
FAN CNT RST
KWH CNT RST

20 LIMITS

20.01
MINIMUM SPEED
-18000 / (no. of pole
pairs) ... Par.
20.02
rpm
20.02
MAXIMUM SPEED
Par.
20.01
... 18000 /
(no. of pole pairs) rpm
Actual signals and parameters
Description
Saves the valid parameter values to the permanent memory.
Note: A new parameter value of a standard macro is saved automatically when
changed from the panel but not when altered through a fieldbus connection.
Saving completed
Saving in progress
Defines the source or constant for value Par.
Parameter index or a constant value. See parameter
the difference.
Defines the source of the control board power supply.
Note: If an external supply is used but this parameter has value INTERNAL,
the drive trips on a fault at power switch off.
Internal (default).
External. The control board is powered from an external supply.
Defines the source or constant for selection PARAM 16.11 of parameter 16.04.
Parameter index or a constant value. See parameter
the difference.
Defines the time delay for drive reset after the power on ackn (DIL) signal is
activated. Can be used for faults generated during drive initialization. See page
338
for a wiring diagram of the power ackn signal.
Setting range in seconds.
Defines the source or constant for parameter
Parameter index or a constant value. See parameter
for information on the difference.
Resets the cooling fan running time counter or kWh counter.
No selection.
Resets the running time counter of the drive cooling fan indicated by actual
signal
01.44
FAN ON-TIME.
Resets the kWh counter indicated by actual signal
Drive operation limits.
Defines the allowed minimum speed. This value is the limit the drive will use in
reverse direction. The limit cannot be set if parameter
Note: The limit is linked to the motor nominal speed setting, that is
parameter 99.08. If
change.
Minimum speed limit.
Note: If the value is positive, the motor cannot be run in the reverse direction.
Defines the allowed maximum speed. This value is the limit the drive will use in
forward direction. The value cannot be set if parameter
Note: The limit is linked to the motor nominal speed setting, that is
parameter 99.08. If
change.
Maximum speed limit
16.08
of parameter
10.04
10.04
16.05.
10.04
01.15
99.04
99.08
is changed, the default speed limit will also
99.08
is changed, the default speed limit will also
FbEq
0
1
16.01.
for information on
-
1
2
for information on
-
0 ... 600
EXT1 STRT PTR
-
0
1
KILOWATT HOURS. 2
= SCALAR.
1 = 1 rpm
99.04
= SCALAR.
1 = 1 rpm