Power ON acknowledge and internal fault reset

The Power ON Ack signal (usually from the main contactor auxiliary contact) is, by
default, programmed to the DIL input on the RMIO board. For more information, see
section
Inputs and Pointers PTR
If the Power ON Ack signal is not connected, the drive is not ready for start.
After the Power ON Ack signal is closed (digital input DIL is TRUE = 1), the drive
generates one internal fault reset after the time defined with parameter
POWER ON RESET TD.
The wiring diagram for the Power ON acknowledge signal is shown below.

Settings

Parameters 16.12, 97.18.
Program features
Programmable digital inputs
on page 63.
Power ON acknowledge
16.12
on page
62
and
Additional information for Digital
Internal fault reset
16.12