ABB ACS800 Firmware Manual page 225

Crane control program
Hide thumbs Also See for ACS800:
Table of Contents

Advertisement

Index
Name/Selection
99.02
APPLICATION
MACRO
CRANE
USER 1 LOAD
USER 1 SAVE
USER 2 LOAD
USER 2 SAVE
99.03
APPLIC RESTORE
NO
YES
99.04
MOTOR CTRL MODE Selects the motor control mode.
DTC
Description
Selects the application macro. See chapter
location EXT1/EXT2
for more information.
Note: When you change the default parameter values of a macro, the new
settings become valid immediately and stay valid even if the power of the drive
is switched off and on. However, backup of the default parameter settings
(factory settings) of each standard macro is still available. See parameter
99.03.
For Crane application
User 1 macro loaded into use. Before loading, check that the saved parameter
settings and the motor model are suitable for the application.
Save User 1 macro. Stores the current parameter settings and the motor
model.
Note: There are parameters that are not included in the macros. See
parameter 99.03.
User 2 macro loaded into use. Before loading, check that the saved parameter
settings and the motor model are suitable for the application.
Save User 2 macro. Stores the current parameter settings and the motor
model.
Note: There are parameters that are not included in the macros. See
parameter 99.03.
Restores the original settings of the active application macro (99.02).
- If a CRANE macro is active, the parameter values are restored to the default
settings (factory settings). Exceptions: parameter settings in parameter group
99 remain unchanged. The motor model remains unchanged.
- If User Macro 1 or 2 is active, the parameter values are restored to the last
saved values. In addition, the last saved motor model are restored. Exceptions:
Settings of parameters
16.05
Note: The parameter settings and the motor model are restored according to
the same principles when a macro is changed to another.
No action
Restoring
Direct torque control mode is suitable for most applications.
Application macros, control
and
99.02
remain unchanged.
FbEq
1
2
3
4
5
0
65535
0
Actual signals and parameters
225