ABB ACS800 Firmware Manual page 142

Crane control program
Hide thumbs Also See for ACS800:
Table of Contents

Advertisement

142
See figures below for control connection using motorized potentiometer
1)
See the wiring diagram on page
if used as power ON ackn signal.
*
To be configured using respective
pointer parameters
rpm
A
Application macros, control location EXT1/EXT2
338
X20
1
VREF
Reference voltage -10 V DC
2
GND
1 kohm < R
X21
1
VREF
Reference voltage 10 V DC
1 kohm < R
2
GND
3
AI1+
not in use 0(2) ... 10 V, R
4
AI1-
5
AI2+
By default, not in use. 0(4) ... 20 mA, R
100 ohm
6
AI2-
7
AI3+
By default, not in use. 0(4) ... 20 mA, R
100 ohm
8
AI3-
9
AO1+
Motor speed 0(4) ... 20 mA
speed, R
10
AO1-
11
AO2+
Output current 0(4) ... 20 mA
nom. current, R
12
AO2-
X22
1
DI1
Forward Start
2
DI2
Reverse Start
3
DI3
Speed Increase
4
DI4
Speed Decrease
5
DI5
Slowdown (0= Slowdown active) *
6
DI6
Brake Acknowledge (1= brake open) *
7
+24 V
+24 V DC, max. 100 mA
8
+24 V
9
DGND1 Digital ground
10
DGND2 Digital ground
11
DI IL
Start interlock (0 = stop)
X23
1
+24 V
Auxiliary voltage output, non-isolated, 24 V
DC, 250 mA
2
GND
X25
1
RO11
2
RO12
3
RO13
X26
1
RO21
2
RO22
3
RO23
X27
1
R031
2
R032
3
R033
< 10 kohm
L
< 10 kohm
L
> 200 kohm
in
0 ... motor nom.
=
< 700 ohm
L
0 ... motor
=
< 700 ohm
L
1)
Relay output 1
Open Brake
Relay output 2
Running
Relay output 3
Inverted fault
=
in
=
in

Advertisement

Table of Contents
loading

Table of Contents