ABB ACS800 Firmware Manual page 158

Crane control program
Hide thumbs Also See for ACS800:
Table of Contents

Advertisement

158
Index
Name/Selection
10.04
EXT1 STRT PTR
-255.255.31 ...
+255.255.31 / C.-
32768 ... C.32767
10.05
EXT2 STRT PTR
-255.255.31 ...
+255.255.31 / C.-
32768 ... C.32767
10.07
NET CONTROL
0
1
10.08
NET REFERENCE
0
1
10.09
SLOW DOWN INPUT Defines the input for the Slowdown command for external control location 1
NOT SEL
DI3 F,DI4 R
DI4 F,DI5 R
DI7 F,DI8 R
DI9 F,DI10 R
PAR 10.19
Actual signals and parameters
Description
Defines the source or constant for value Par.
parameter
10.01
EXT1 STRT/STP/DIR.
Parameter index or a constant value:
- Parameter pointer: Inversion, group, index and bit fields. The bit number is
effective only for blocks handling boolean inputs.
- Constant value: Inversion and constant fields. Inversion field must have value
C to enable the constant setting.
Defines the source or constant for value Par. 10.05 of parameter
STRT/STP/DIR.
Parameter index or a constant value. See parameter
for information on the difference.
When active, fieldbus overrides the selection of parameter
STP/DIR. Fieldbus Control Word (except bit 11) is enabled when EXT1 is
selected as the active control location.
Note: Only visible with the Generic Drive communication profile selected
(98.07).
Note: The setting is not saved in the permanent memory (will reset to zero
when power is switched off).
Inactive
Active
When active, fieldbus overrides the selection of parameter
SELECT. Fieldbus reference REF1 is enabled when EXT1 is selected as the
active control location.
Note: Only visible with the Generic Drive communication profile selected
(98.07).
Note: The setting is not saved in the permanent memory (will reset to zero
when power is switched off).
Inactive
Active
(EXT1) and 2 (EXT2). When the command is active, the drive limits the speed
to the slowdown reference defined with parameter
No Slowdown selection.
Slowdown command through digital input 3 and digital input 4. Slowdown
active in forward direction (UP) when DI3 = 0, inactive when DI3 = 1.
Slowdown active in reverse (down) direction when DI4 = 0, inactive when
DI4 = 1.
Slowdown command through digital input 4 and digital input 5.
See DI3 F,DI4 R selection.
Slowdown command through digital input 7 and digital input 8.
See DI3 F,DI4 R selection.
Slowdown command through digital input 9 and digital input 10.
See DI3 F,DI4 R selection.
Slowdown command through parameter 10.19. This selection can be used if
only one DI is used for up and down directions in parallel. Slowdown active
when pointer value = 0, inactive when pointer value = 1.
10.04
EXT1 STRT PTR of
10.02
10.04
EXT1 STRT PTR
10.01
EXT1 STRT/
11.03
EXT REF1
11.12
SLOW DOWN REF.
FbEq
-
EXT2
-
0
1
0
1
1
2
3
4
5
6