External Control - ABB ACS800 Firmware Manual

Crane control program
Hide thumbs Also See for ACS800:
Table of Contents

Advertisement

External control

When the drive is in external control, the commands are given through standard I/O
terminals (digital and analogue inputs), optional I/O extension modules and/or the
fieldbus interface. In addition, it is also possible to set the control panel as the source
for the external control.
External control is indicated by a blank on the panel display or with an R in those
special cases when the panel is defined as a source for the external control.
You can connect the control signals to two external control locations, EXT1 or EXT2.
Depending on the selection, either one is active at a time. This function operates on
a 20 ms time level.
The figure below illustrates the use of the external control locations.
10.01
EXT1 STRT/STP/DIR
11.03
EXT REF1 SELECT
10.02
EXT2 STRT/STP/DIR
11.06
EXT REF2 SELECT
1
->1242 rpm
External control through the Input/
Output terminals, or through the
fieldbus interfaces
EXT1
Stand-alone mode
Homing
EXT2
Master/Follower
Synchro control
I
1 R ->1242 rpm
External control by control panel
CH2
I
11.02
EXT1/EXT2 SELECT
Program features
55